PowerFlex® 700S and 700H Frame 10 Replacement Power Structures

13

Figure 6 Termination Points on 700S Boards

Connections to the 700H Control

When installing a power structure in a PowerFlex 700H drive, you must
make the following connections between the ASIC and Fiber Optic Adapter
and Rectifier boards:

J4 J5

J8

J8

J10

J12

J6

J5

J9

J11

J14

J7

J13

J5

J1

Power Supply Voltage Feedback Board

Fiber Optic Interface Board

Common Mode Filter Board

Connect this component: termination point in
the Power Structure to …

…this component : termination point on the
Control Frame

ASIC Board : H1 (fiber optic connector)

Fiber Optic Adapter Board : H1
(fiber optic connector)

ASIC Board : H2 (fiber optic connector)

Fiber Optic Adapter Board : H2
(fiber optic connector)

ASIC Board : H3 (fiber optic connector)

Fiber Optic Adapter Board : H3
(fiber optic connector)

ASIC Board : H4 (fiber optic connector)

Fiber Optic Adapter Board : H4
(fiber optic connector)

ASIC Board : H5 (fiber optic connector)

Fiber Optic Adapter Board : H5
(fiber optic connector)

ASIC Board : H6 (fiber optic connector)

Fiber Optic Adapter Board : H6
(fiber optic connector)