Rockwell Automation 20D PowerFlex 700H/S Frame 10 Replacement Power Structure User Manual
Page 13
 
PowerFlex® 700S and 700H Frame 10 Replacement Power Structures
13
Figure 6 Termination Points on 700S Boards
Connections to the 700H Control
When installing a power structure in a PowerFlex 700H drive, you must 
make the following connections between the ASIC and Fiber Optic Adapter 
and Rectifier boards: 
J4 J5
J8
J8
J10
J12
J6
J5
J9
J11
J14
J7
J13
J5
J1
Power Supply Voltage Feedback Board
Fiber Optic Interface Board
Common Mode Filter Board
Connect this component: termination point in 
the Power Structure to …
…this component : termination point on the 
Control Frame
ASIC Board : H1 (fiber optic connector)
Fiber Optic Adapter Board : H1 
(fiber optic connector)
ASIC Board : H2 (fiber optic connector)
Fiber Optic Adapter Board : H2 
(fiber optic connector)
ASIC Board : H3 (fiber optic connector)
Fiber Optic Adapter Board : H3 
(fiber optic connector)
ASIC Board : H4 (fiber optic connector)
Fiber Optic Adapter Board : H4
(fiber optic connector)
ASIC Board : H5 (fiber optic connector)
Fiber Optic Adapter Board : H5 
(fiber optic connector)
ASIC Board : H6 (fiber optic connector)
Fiber Optic Adapter Board : H6 
(fiber optic connector)