Insulate Terminal X4 on the Rectifier Circuit Board

Follow the lettered steps below to insulate terminal X4 on the Rectifier
circuit board (refer to

Figure 2 on page 5

for Rectifier board location):

Important: Do not install the screw and washer that was removed from this

connection.

Task

Description
Remove the screw from the X4 connection on the Rectifier circuit board.

Insulate the top and bottom of the X4 connection on the Rectifier circuit board.

A

B

X1

X4

X41

X1

X4

X41

Rectifier Circuit Board