Maintenance, Motor storage, Linear encoder carriage/heat sink – Rockwell Automation LDL Ironless Linear Servo Motors User Manual
Page 19: Maintenance motor storage, Linear encoder, Carriage/heat sink
 
Publication LDL-UM001A-EN-P - March 2009
19
Start Chapter 2
stops. The following diagram shows a minimal system with 
mechanical stops.
Linear Encoder
Your linear motor components needs to be integrated with a linear 
encoder purchased from a third party.
Carriage/Heat Sink
The linear motor coil requires a heat sink to maintain performance. 
The heat sink requires a minimal mass and surface area as shown on 
. It can as so serve as the carriage in moving coil system or be
designed into the base in moving magnet system.
Maintenance
Linear motors require no maintenance when operated in a relatively 
clean environments. For operation in harsh and dirty environments, 
minimal cleaning is recommended every 6 months. 
Clean the metallic debris and other contaminants from the air gap. Use 
a strip of masking tape to effectively remove the metal debris. Apply a 
strip of tape in the magnet channel and then remove it. 
Motor Storage
Motor storage area should be clean, dry, vibration free, and have a 
relatively constant temperature. If a motor is stored on equipment, it 
should be protected from the weather. All motor surfaces subject to 
corrosion should be protected by applying a corrosion resistant 
coating.
Mechanical Stops
Mechanical Stops
Encoder readhead
Encoder strip
Carriage/Heat Sink