Mounting and wiring two identical coils in tandem, Cables exit to the right – Rockwell Automation LDL Ironless Linear Servo Motors User Manual
Page 35
 
Publication LDL-UM001A-EN-P - March 2009
35
Wiring the LDL-Series Linear Motor Chapter 5
Mounting and Wiring Two 
Identical Coils in Tandem
This type of installation requires custom motor database file which is 
available upon request. Contact Application Engineering at 
631.344.6600 to request this file.
The following tables and diagrams show the wiring and spacing for
two identical coils mechanically top mounted
(1)
to the same plate and
driven by one amplifier. There are three configurations shown here 
for mounting motors in tandem: power and encoder cables exiting on 
the right, the center, and on opposite ends.
Cables Exit to the Right
If mounting coils in tandem, such that the power cables exit both of 
the coils on right side as shown, use the following table to find 
mounting distance and phase wiring.
(1) Contact Application Engineering (631.344.6600) for side mounting of the coils.
ATTENTION
Coils must have identical part numbers. Using mis-matched 
coils will cause a hazardous condition resulting in damage to 
the equipment and a possible fire.
L1
Coil #1 is the master
Coil #1
Coil #2
Hall Effect
Phase Wiring for Right Exit Power Cables
L1
mm (in.)
Coil # 1
Master
(1)
Coil # 2 
Slave
(2)
Amplifier
Phase
80 (3.15)
Red
White
U
White
Black
V
Black
Red
W
120 (4.72)
Red
Black
U
White
Red
V
Black
White
W