Installation
2-37
Step 4.
Reattach the Cover
Step 4.1 Remove enough tabs on the faceplate breakout panel to allow the Network
Drop Cable through.
Step 4.2 Route the Network Drop Cable through the breakout panel.
Step 4.3 Reconnect the keypad/display cable to the cover.
Important: For 24 to 30 amp drives, fold and slide the keypad/display cable under the
heatsink at the top of the drive before attaching the cover.
Step 4.4 Reattach the cover using the single faceplate screw.
Step 4.5 Reconnect all faceplate wiring.
This completes the hardware installation of the AutoMax Network option board. Do not
remove the lockout and tag until you have completed section 2.10, which provides
instruction on connecting to the AutoMax network.
Figure 2.20 – Installing the AutoMax Network Option Board in GV3000/SE Bookshelf Drive
Regulator Board
Keypad/Display
Regulator Board
Ribbon Cable
Cable Connector
AutoMax Network
Option Board