Drive Configuration
3-9
P.066 to P.069 Network Output Register 1 Source through
Network Output Register 4 Source
These parameters
select the signal
written to the option
port network output
registers 1 through 4.
See figure 3.1.
Parameter Range:
0 = (P.066) Motor Kw display value
(P.067) Motor torque display value
(P.068) Output power factor
(P.069) Encoder counter (x4)
1 = Speed reference rate limit output (vector only)
2 = Speed reference at the ref/fdbk summing
junction (includes
OCL
output and current
compounding) (vector only)
3 = Speed loop feedback (vector only)
4 = Speed loop error (vector only)
5 = Speed PI output (vector only)
6 = Outer control loop feedback (vector only)
7 = Outer control loop error (vector only)
8 = Outer control loop output (vector only)
9 = Terminal strip analog input normalized to speed
(see drive software instruction manual)
10 = Terminal strip analog input scaled (see drive
software instruction manual)
11 = Torque reference (vector only)
12 = Torque feedback (vector only)
Default Setting:
0
Parameter Type:
Tunable
Refer also to parameters:
N/A