MP-Series Integrated Gear Motor Installation Instructions

Publication MP-IN003C-EN-P — April 2003

Housing and Output Flange Connections

The following table provides ISO 898-1 mounting bolt strength class
requirements for the motor housing, and tightening torques for
connecting the motor housing and the ISO 9409 compliant output flange
to your assembly. Apply a high-temperature, medium-strength threadlock
adhesive to the mounting bolts.

IMPORTANT

A loose or slipping connection will cause system
instability and may damage the MP gear motor.

All connections between the assembly and the MP gear
motor must be rigid to achieve acceptable response from
both the motor and the system.

Periodically inspect connections to verify their rigidity.

Motor Bolt

Strength

Grade
ISO 898-1

Torque

Motor Housing

1

Output

Flange

1

Nm (lb-in.)

Nm (lb-in.)

MPG-A004

10.9

4.1 (36.3)

8.1 (72)

MPG-A010, MPG-B010

10.9

8.1

(72)

14.0

(124)

MPG-A025, MPG-B025

10.9

8.1

(72)

14.0

(124)

MPG-A050, MPG-B050

10.9

14.0

(124)

34.0

(301)

MPG-A110,

MPG-B110

10.9

34.0 (301) 67.0 (593)

1

Refer to Mounting Dimensions beginning on page 10 for hole dimensions.