Cables and connector kits, Building and installing cables – Rockwell Automation MPG-xxxx Integrated Gear Motor User Manual

Page 28

Advertising
background image

28

MP-Series Integrated Gear Motor Installation Instructions

Publication MP-IN003C-EN-P — April 2003

Cables and Connector Kits

Factory manufactured feedback and power cables are available in
standard cable lengths. They provide environmental sealing and proper
shield termination to an IP66 rating, which exceeds the MP gear motor’s
IP64 rating. For a complete listing of available cables refer to your drive’s
installation manual, contact your nearest Rockwell Automation sales
office, or access the information from the web sites referenced in Related
Documentation
o
n page 30.

Building and Installing Cables

Knowledgeable cable routing and careful cable construction improves
system electromagnetic compatibility (EMC).

To build and install cables, perform the following steps:

1. Keep wire lengths as short as physically possible.

2. Route signal cables (encoder, serial, analog, and brake) away from

motor and power wiring.

3. Separate cables by 0.3 m (1 ft) minimum for every 9 m (30 ft) of

parallel run.

4. Ground both ends of the encoder cable shield and twist the signal wire

pairs to prevent electromagnetic interference (EMI) from other
equipment.

ATTENTION

!

High voltage can be present on the shield of a power
cable, if the shield is not grounded.

Ensure there is a connection to ground for any power
cable shield.

Failure to observe these safety procedures could result in
personal injury or damage to equipment.

Advertising