Holding brake – Rockwell Automation MPG-xxxx Integrated Gear Motor User Manual

Page 27

Advertising
background image

MP-Series Integrated Gear Motor Installation Instructions

27

Publication MP-IN003C-EN-P — April 2003

Holding Brake

A 24V dc holding brake is an option on the MP-Series Integrated Gear
Motor. The following table

s

provide specifications on the brake.

IMPORTANT

Ensure that proper polarity is maintained when wiring a
brake connector.

Description Gear

Ratio

MPG-A004-xxx MPG-A010-xxx,

MPG-B010-xxx

MPG-A025-xxx,
MPG-B025-xxx

Type Permanent

Magnet

Holding Torque

-031

25 Nm

(221 lb-in.) 68 Nm

(602 lb-in.) 68 Nm

(602 lb-in.)

-091

32 Nm

(283 lb-in.) 80 Nm

(708 lb-in.) 205 Nm (1819 lb-in.)

Backlash

None with brake engaged

Voltage Input

21.6 to 25.4V dc

Current Input 24V dc,
20

o

to 30

o

C (68

o

to 86

o

F)

~0.33 A

~0.45 A

~0.45 A

Coil Resistance at 20

o

C (68

o

F)

67 to 77 Ohms

48.7 to 56 Ohms

48.7 to 56 Ohms

Coil Resistance at 40

o

C (104

o

F), operating

at maximum continuous stall torque

72 to 83 Ohms

52 to 61 Ohms

48 to 55 Ohms

Release Time Delay
(when voltage is applied)

22 ms

25 ms

25 ms

Engage Time
(when voltage is removed)

7 ms

6 ms

6 ms

Description Gear

Ratio

MPG-A050-xxx,
MPG-B050-xxx

MPG-A110-xxx,
MPG-B110-xxx

Type Permanent

Magnet

Holding Torque

-031

193 Nm

(1711 lb-in.)

693 Nm

(6137 lb-in.)

-091

500 Nm

(4425 lb-in.)

1300 Nm

(11506 lb-in.)

Backlash

None with brake engaged

Voltage Input

21.6 to 25.4V dc

Current Input 24V dc,
20

o

to 30

o

C (68

o

to 86

o

F)

~0.5 A

~1.0 A

Coil Resistance at 20

o

C (68

o

F)

44.7 to 51.3 Ohms

22.4 to 25.6 Ohms

Coil Resistance at 40

o

C (104

o

F), operating

at maximum continuous stall torque

48 to 55 Ohms

24 to 28 Ohms

Release Time Delay
(when voltage is applied)

35 ms

35 ms

Engage Time
(when voltage is removed)

7 ms

7 ms

Advertising