Motor load force ratings – Rockwell Automation MPG-xxxx Integrated Gear Motor User Manual

Page 23

Advertising
background image

MP-Series Integrated Gear Motor Installation Instructions

23

Publication MP-IN003C-EN-P — April 2003

Motor Load Force Ratings

Motors are capable of operating with a sustained shaft load. The radial
and axial load force location is shown in the figure, and maximum values
for motors are in the following tables.

Figure 2
Load Forces on Shaft

The following tables represent 20,000 hour L

10

bearing fatigue life at

various loads and speeds. This 20,000 hour life does not account for
possible application-specific life reduction that may occur due to bearing
grease contamination from external sources, improper alignment, or
excessive loading.

Axial load force applied at shaft centerline

Radial load force applied at mounting end of output flange

Advertising