What this kit contains, Recommended tools, Installation – Rockwell Automation 20B PowerFlex 700 Dynamic Brake Kit User Manual

Page 2: Remove power from the drive

Advertising
background image

2

Rockwell Automation Publication PFLEX-IN030A-EN-P - July 2014

PowerFlex 700/700S Frame 5 Drives 600/690V Brake Bus Bar Insulator Installation

What This Kit Contains

One piece of Tyco Electronics heat shrink tube (1.5…2.0 in.), part number
RNF-3/4-1-BK-STK. Note: If this part is lost or damaged, it is acceptable to use
another 1.5…2.0 in. piece of UL Listed equivalent heat shrink tube in its place.

Recommended Tools

The following list of tools is provided for your reference to disassemble and
reassemble the drive and components. You may need more tools than are listed
based on your situation.

Volt ohm meter
Torque wrench (metered in N•m or lb•in) with a Torx head bit
Needle-nose pliers
Heat gun

Installation

Remove Power from the Drive

1. Turn off and lock out input power. Wait 5 minutes.
2. Verify that there is no voltage at the drive’s input power terminals.
3. Check the DC bus voltage at the power terminals by measuring between

the +DC and –DC terminals, between the +DC terminal and the chassis,
and between the –DC terminal and the chassis. The voltage must be zero
for all three measurements.

ATTENTION: To avoid an electric shock hazard, ensure that all power has been
removed before proceeding. In addition, before servicing, verify that the
voltage on the bus capacitors has discharged. Check the DC bus voltage at the
Power Terminals by measuring between the +DC and -DC terminals, between
the +DC terminal and the chassis, and between the -DC terminal and the
chassis. The voltage must be zero for all three measurements.

Remove power before making or breaking cable connections. When you remove or
insert a cable connector with power applied, an electrical arc can occur. An
electrical arc can cause personal injury or property damage by:

sending an erroneous signal to your system’s field devices, causing unintended

machine motion.

causing an explosion in a hazardous environment.

Electrical arcing causes excessive wear to contacts on the module and its mating
connector. Worn contacts can create electrical resistance.

L1

L2

L3

O

I

Advertising