1 genlock, 0 tc in, 1 tc value – AJA Ki Pro User Manual

Page 59: 2 tc type, 1 genlock 8.0 tc in 8.1 tc value 8.2 tc type

Advertising
background image

Ki Pro v3.2

www.aja.com

59

Figure 20. Down Conversion Illustrations

6.1 GENLOCK

This parameter selects source of reference video used to genlock to during playback. Ki
Pro always genlocks to the selected input during capture. These are the options:

8.0 TC IN

This parameter selects the source of timecode start from those available. These are the
options:

8.1 TC VALUE

This parameter selects the starting hour for timecode when 8.0 is set to TC Value. These
are the options:

8.2 TC TYPE

This parameter selects drop frame or non-drop frame timecode. These are the options:

1 6

9

Anamorphic

Letterbox

4

3

16:9 Downconverts To

These displays on 4:3

Crop

INPUT
CMP Y
FREERUN (default)

Use the currently selected input as the Genlock source
Use component Y as the Genlock source
Free run mode: Ki Pro syncs to its own timebase and is not

locked to an external source

TC VALUE (default)
SDI RP188

LTC
FW400

TIME OF DAY
RS422

Use the value specified in parameter 8.1 TC VALUE
Use the timecode read from the embedded RP188 metadata

in the SDI input

Use timecode from the LTC input connector
FireWire TC value is used (FW400 is presented only if

parameter 35.2 is set to FW Only)

Set TC to “Time of Day” clock (CONFIG parameter 55.6)
RS422 in-point TC value is used for the start value of a

recording (presented only if 35.2 is set to RS422 Only)

00:00:00:00 to 23:00:00:00
(Default: 01:00:00:00)

Use the ADJUST buttons to select a timecode hour.
For example: “01:00:00:00”, “02:00:00:00”, etc.