Baumfolder BAUM20: Ifold Service Manual User Manual

Page 12

Advertising
background image

18.

Move the run/main jumper (currently on the 1

st

and 2

nd

pins) to the 2

nd

and 3

rd

pins; this will place the machine

in maintenance mode at power up. See jumper location in Figure 9.

19.

Reconnect power to the machine,

NOTE: I-FOLD COMPUTER FUSES A-F1 and A-F2 ARE NOT INSTALLED AT

THIS TIME

. T

urn on main power switch.

20.

Folder will wake up in maintenance mode. Both displays will light up with “8” in each segment. T

h

en a diagnostic

message will display in display 2. T

hen the new software version will display in display 2, “dct 9.9.b”. T

hen the

machine will switch to maintenance mode, display will display ether “oFF” or “dSP” and display 2 will display the

machine model i.e. (P-2020).

21.

Set Serial Port operating mode. Note display 1, Figure 10, this display needs to display “nEt”. T

o toggle between

modes by pressing button 1, or button 2, until “nEt” is displayed.

Figure 10

Button 1

Display 1

Button 2

Display 2

Button 3

10

Button 4

Button 5

Button 6

Button 7

Page 10 of 45

TP10497