18.
Move the run/main jumper (currently on the 1
st
and 2
nd
pins) to the 2
nd
and 3
rd
pins; this will place the machine
in maintenance mode at power up. See jumper location in Figure 9.
19.
Reconnect power to the machine,
NOTE: I-FOLD COMPUTER FUSES A-F1 and A-F2 ARE NOT INSTALLED AT
THIS TIME
. T
urn on main power switch.
20.
Folder will wake up in maintenance mode. Both displays will light up with “8” in each segment. T
h
en a diagnostic
message will display in display 2. T
hen the new software version will display in display 2, “dct 9.9.b”. T
hen the
machine will switch to maintenance mode, display will display ether “oFF” or “dSP” and display 2 will display the
machine model i.e. (P-2020).
21.
Set Serial Port operating mode. Note display 1, Figure 10, this display needs to display “nEt”. T
o toggle between
modes by pressing button 1, or button 2, until “nEt” is displayed.
Figure 10
Button 1
Display 1
Button 2
Display 2
Button 3
10
Button 4
Button 5
Button 6
Button 7