11.

T

he comm

unication board will sit on the right side of din rail that sits above the transformer, as shown in Figure 5.

Run the communication cable to the top of the communication board and will wire into the two rows of terminals.

Add an extra 2” to 3” of cable, and then cut cable to that length. Strip back 4” of cable jacket and shielding to expose conductors. Cut pink, brown & green conductors 1” shorter than the other three conductors. Strip

approximately 5/16” of wire insulation from each conductor. Wire communication cable into the communication

board terminal block as shown in figure 6.

Figure 5

Communication Cable

T

erminal Block

Din Rail

Cable

Orientation Stripe

Ribbon Cable

Communication Board

DCT500 B

oard

5