Baumfolder BAUM20: Ifold Service Manual User Manual
Page 13
11
22.
Go to the advance settings by pressing button 3, Figure 10. Value A00 should now be displayed in display 1. Use
button 4 and button 5 to change the value of display 1. By pressing button 5 the value increases, set value to
“A03”. A value of “0” should now be displayed in display 2. Use button 6 and button to change its value to “1”. Next value “A04” must be displayed in display 1, use button 5. T
he value of A04 is displayed in display 2 and must
be change to “nEt 1”. Press button 6 or 7 to change the value. Press button 3 times to exit program mode.
23.
Check the voltage to the I-fold computer by taking a voltmeter, setting it to VOLTS AC and look at the voltage across the top of the new fuse blocks A-F1 and A-F2. The re
ading should be between 200 to 244 Volts. If not, go
back and troubleshoot power circuit, before fuses are installed.
24.
Power down the machine by switching off main power switch. Move the run/main jumper (currently on the 2
nd
and 3
rd
pins) back to the 1
st
and 2
nd
pins; this will place the machine back in run mode at power up. See jumper
location in Figure 9.
25.
Install .5 amp fuses into fuse blocks A-F1 and A-F2. Reinstall cover over the DCT
500 board. Cleanup enclosure
and close up enclosure.
26.
T
urn on main power switch and let the machine wake up normally.
27.
Go into the machine setup mode by pressing button 3, see Figure 9. Use button 1, or button 2, to get “P20” to display in display 1. Use button 4, or button 5, to display “P22” in display 1, Display 2 should now read “Addr 1”.
Use button 4, or button 5. to change display 1 to read “P24”, Display 2 will read “nEt 0”. Use button 6, or button
7, to change display 2 so it reads as “nEt 1”. Press button 1 once then button 3 once to leave setup mode.
28.
If I-fold computer is not up at this time check power switch on the computer, it must be switched on, see Figure 1.
29.
Place the removed chip, from instruction 13 back into the box the new chip came in and please send it back to
Baumfolder for reprogramming.
BAUMFOLDER CORP.
ATTN. MARK WALKER
1660 Campbell Road
Sidney, Ohio 45365
Page 11 of 45
TP10497