Troubleshooting – Bendix Commercial Vehicle Systems EC-15 ANTILOCK CONTROLLER ASSY 4/08 User Manual

Page 12

Advertising
background image

12

TROUBLESHOOTING

GENERAL

While the EC-15

controller diagnostic display locates a

specific problem area, it is still necessary to confirm whether
the problem resides in the component itself or the wiring.
Basically the troubleshooting procedure that follows is
devoted to narrowing the problem to either the wiring or a
specific antilock component.

TROUBLESHOOTING TIPS

1. All troubleshooting begins by observing the antilock

condition lamp on the dash. Troubleshooting should
begin by first performing the “Initial Start-up Procedure”
and following the directions contains in it.

2. The troubleshooting technician should record all findings

and the action taken during the troubleshooting process.

3. No voltage or resistance tests are performed into the

EC-15

controller. All voltage and resistance tests are

performed by beginning at the wire harness half of the
connector and moving AWAY from the EC-15

controller

toward an antilock system component (modulator, wheel
speed sensor, etc.)