Troubleshooting – Bendix Commercial Vehicle Systems EC-15 ANTILOCK CONTROLLER ASSY 4/08 User Manual

Page 19

Advertising
background image

19

ARE RESISTANCE
VALUES CORRECT?

REPEAT “INITIAL START-UP
PROCEDURE”. IF THIS
TEST STEP HAS REPEATED
TWICE - REPLACE THE
EC-15

CONTROLLER.

INSPECT CONNECTOR AND
RECONNECT TO EC-15

CONTROLLER. TURN IGNITION ON
AND PASS MAGNET OVER
RESET ON EC-15

CONTROLLER.

NOTE REACTION OF RED LEDS.

PROBE CONNECTOR WITH VOLT/OHM METER AND NOTE
THAT PROPER RESISTANCE VALUES ARE OBTAINED FOR
MODULATOR BEING TESTED. FIGS. 7 AND 8. RESISTANCE
VALUES HERE FOR BENDIX

®

M-21

MODULATOR (FIG. 5).

HOLD TO SOURCE:

READ 3.5 TO 5 OHMS

EXHAUST TO SOURCE:

READ 3.5 TO 5 OHMS

EXHAUST TO HOLD:

READ 7 TO 10 OHMS

SOURCE TO BATTERY POWER:

NO CONTINUITY

SOURCE TO GROUND:

NO CONTINUITY

NOTE: SOURCE TO BATTERY TEST NOT REQUIRED FOR
CONNECTOR 2, (REAR) DEUTSCH CONNECTOR FIGURE 7.

TEST REAR MODULATOR ON

OPPOSITE SIDE OF VEHICLE GO

TO BEGINNING THIS SECTION

(VI) AND RETEST

TURN IGNITION OFF. REFER TO
FIGURES 7 AND 8. DISCONNECT
WIRE HARNESS CONNECTOR
FROM EC-15

CONTROLLER.

YES

FRONT OR REAR

MODULATOR?

GO TO SECTION VI B AND

CONTINUE TESTING

NO

REPLACE EC-15

CONTROLLER

IF FAILURE PERSISTS, REPLACE
THE EC-15

CONTROLLER.

ARE ANY RED LED’S

ILLUMINATED?

GO TO SECTION IV

“INSPECTION FOR

ILLUMINATED RED

LEDS” AND RETEST.

TROUBLESHOOTING

SECTION VI A - TESTING THE MODULATOR

SAME RED LED’S

ILLUMINATED?

START HERE