Bendix Commercial Vehicle Systems EC-15 ANTILOCK CONTROLLER ASSY 4/08 User Manual

Page 20

Advertising
background image

20

GO TO MODULATOR, INSPECT WIRING CONNECTOR.
DISCONNECT CONNECTOR AND TEST RESISTANCE
BETWEEN PINS ON MODULATOR, RESISTANCE VALUES
FOR BENDIX

®

M-21

MODULATOR (FIGURE 5).

HOLD TO SOURCE:

READ 3.5 TO 5 OHMS

EXHAUST TO SOURCE:

READ 3.5 TO 5 OHMS

EXHAUST TO HOLD:

READ 7 TO 10 OHMS

TEST EACH PIN TO VEHICLE GROUND AND NOTE NO
CONTINUITY.

RECONNECT CONNECTOR TO MODULATOR.
TURN IGNITION ON AND PASS MAGNET OVER
RESET ON EC-15

CONTROLLER. NOTE

REACTION OF RED LEDS.

ARE ANY RED LED’S
ILLUMINATED?

RESISTANCE READINGS
CORRECT?

START HERE FROM

SECTION VI A

REPLACE THE MODULATOR

NO

YES

GO TO SECTION IV “INSPECTION FOR

ILLUMINATED LEDS” AND RETEST.

REPAIR OR REPLACE

MODULATOR WIRE HARNESS.

SAME RED LED’S

ILLUMINATED?

REPEAT THE “INITIAL

START-UP PROCEDURE”

TROUBLESHOOTING

SECTION VI B - TESTING THE MODULATOR

NO

YES

NO

YES