Troubleshooting – Bendix Commercial Vehicle Systems EC-15 ANTILOCK CONTROLLER ASSY 4/08 User Manual

Page 15

Advertising
background image

15

TROUBLESHOOTING

SECTION II - INSPECTION FOR ILLUMINATED LEDS

START HERE

YES (ON)

YES

YES

YES

NO (OFF)

NO

NO

NO

GO TO SECTION IV
“INSPECTION FOR
ILLUMINATED LEDS”.

NOTE AND RECORD
THE CONDITION OF
ALL RED LEDS

ARE ANY RED LEDS
ILLUMINATED?

GO TO SECTION V
“TESTING FOR POWER
TO THE EC-15

CONTROLLER”

ARE ANY RED
LED’S
ILLUMINATED?

CHECK CLOSELY
AND NOTE IF GREEN
LED IS ILLUMINATED

INSPECT EC-15

CONTROLLER FOR
PRESENCE OF
ILLUMINATED LEDS
AND RECORD.

GO TO SECTION V “TESTING
FOR POWER TO THE EC-15

CONTROLLER”.

GO TO SECTION VIII “TESTING
FOR FALSE FAILURE INDICATION
- CAUSED BY DASH LAMP
RELAY”.

REPLACE

THE EC-15

CONTROLLER

IS GREEN LED FLASHING?