EZ-SCREEN

®

AC Interface Box

Models EZAC-E-QE8 and EZAC-E-QE8-QS3

• Power source for emitters only

• No Test input available

• 8-pin M12 Euro-style connection to emitter, plus

Model

EZAC-E-QE8: hard-wired power and ground inputs (see Figure 10)

Model

EZAC-E-QE8-QS3: 3-pin Mini-style connector for power and ground inputs (see

Figure 11)

Models EZAC-E-QE5 and EZAC-E-QE5-QS5

• Power source for emitters only

• Test input available

• 5-pin M12 Euro-style connection to emitter, plus

Model

EZAC-E-QE5: hard-wired power, ground and test inputs (see Figure 10)

Model

EZAC-E-QE5-QS5: 5-pin Mini-style connector for power, ground inputs, and test

inputs (see Figure 12)

.EUTRAL

,INE

,

.

4%34

 6

4%34

4%34

[

4%34

AVAILABLE

FOR

%:!# % 1%

4ERMINAL

'ND

%:!# % 1%

%:!# % 1%

.EUTRAL

,INE

'ND

%:!# % 1% 13

,

.

 6

"ROWN

"LUE

'REEN9ELLOW







.EUTRAL

,INE

,

.

4%34

 6

4%34

4%34

'ND

%:!# % 1% 13

"ROWN











Figure 11. Hookup – model EZAC-E-QE8-QS3 (3-pin Mini-style QD)

Figure 1. Hookup – model EZAC-E-QES-QS5 (5-pin Mini-style QD)

Figure 10. Hookup – models EZAC-E-QE8 and EZAC-E-QE5

(Hard-wired)

3-Pin Mini-Style Power Connector

Male Face View

5-Pin Mini-Style Output Connector

Male Face View

Mating Cable: QDS-3..C

Mating Cable: QDS-5..C

Pin

Color

Function

Pin

Color

Function

1

Green/Yellow

Gnd/PE

1

Black

TEST #1

2

Brown

Line

2

Blue

Neutral

3

Blue

Neutral

3

Green/Yellow

Gnd/PE

4

Brown

Line

5

White

TEST #2

'REEN9ELLOW

WIRE

"ROWN

WIRE

"LUE

WIRE

"LACK

7HITE

"ROWN

"LUE

'REEN9ELLOW

WARNING ...

Electrical

Connection

Electrical hookup must be made by a qualified
electrician, and must comply with NEC (National
Electrical Code) and local standards. Also, make
no more connections to the EZAC.. interface box
than are described in this document.

Connection of other wiring or equipment to
the box could result in serious bodily injury
or death.