The EZ-SCREEN AC Interface Box (EZAC Series) is powered by 100-250V ac.
EZAC-R.. models can supply one EZ-SCREEN receiver, a single emitter-receiver pair, or two
cascaded emitter-receiver pairs; see Figure 4. Emitter-only models (EZAC-E..) can supply up
to four cascaded emitters, and have no output circuitry.

The integrated interface module, located on a replaceable PC-board, converts the
EZ-SCREEN receiver OSSD output signals into isolated redundant output channels with an
8 amp / 250V ac/dc switching capacity for ac or dc safety circuits (see Models on page 1 for
output descriptions). The outputs of the interface module follow the action of the EZ-SCREEN
OSSD outputs, with a 10 millisecond response time in turning OFF, and approximately 10
millisecond delay in turning ON. All models feature external device monitoring (EDM) in the
form of 1-Ch, 2-Ch or power monitoring.

All models have one 8-pin M12 Euro-style QD to connect to the EZ-SCREEN receiver or
emitter. Other connections are dependent on model; see page 1. Hookups, therefore, are also
model-dependent; see pages 6-9. See pages 14 and 15 for cabling options.

Indicators

A bicolor LED indicates the output contact status of internal relays K1 and K2. (Emitter-only
models have a Green Power ON/OFF indicator.)

®

0/7%2

25.

/540543

'2%%.

2%$

2%3%4

®

0/7%2

Green/Red LED

Status Indicator

Keyed Reset Switch

QD or Cable

Ports (x)

Receiver/Emitter

Connections

Figure 1. Features

LED Status

Power

K1 and K

N.O. Output

N.C. Output

Light Screen

ON Green

ON

Energized

Closed

Open

Clear and reset

ON Red

ON

De-energized

Open

Closed

Blocked, latched,
or locked out

OFF

No ac power

De-energized

Open

Closed

OFF

WARNING . . .

This Interface

Box is not a point-of-operation

guarding device, as defined by OSHA
regulations.
It is necessary to install point-of-operation
guarding devices, such as safety light screens
and/or hard guards, to protect personnel from
hazardous machinery. Failure to install point-
of-operation guards on hazardous machinery