Specifications, Performance curves – Banner U-GAGE T30U—Level Control User Manual

Page 5

Advertising
background image

Specifications

Proximity Mode Range

“A” suffix models: 150 mm (5.9 in) min. near limit; 1 m (39 in) max. far
limit
“B” suffix models: 300 mm (11.8 in) min. near limit; 2 m (79 in) max.
far limit

Supply Voltage

12 to 24V dc (10% max. ripple) at 90 mA, exclusive of load

Supply Protection Circuitry

Protected against reverse polarity and transient voltages

Output Configurations

SPST solid-state switch; choose NPN (current sinking) or PNP (current
sourcing) models

Output Ratings

Dual Discrete Outputs: 100 mA maximum, total – both outputs

OFF-state leakage current: less than 10 microamps
ON-state saturation voltage: less than 1V at 10 mA and less than
1.5V at 100 mA

Output Protection

Protected against continuous overload and short-circuit; transient over-
voltage; no false pulse on power-up

Output Response Time

“A” suffix models: 48 milliseconds
“B” suffix models: 96 milliseconds

Sensing Performance

Sensing repeatability: ±0.25% of distance
Minimum window size: 10 mm (0.4 in)
Hysteresis of discrete output: 2.5 mm (0.10 in)

Adjustments

Sensing window limits: TEACH-mode programming of near and far
window limits may be set using membrane push buttons on sensor or
remotely via TEACH input. Window limits may be programmed separate-
ly, or together

Construction

Molded reinforced thermoplastic polyester housing

Environmental Rating

Leakproof design is rated IEC IP67, NEMA 6P

Connections

2 m (6.5 ft) or 9 m (30 ft) 5-conductor PVC-covered attached cable, or 5-
pin Euro-style quick-disconnect fitting

Operating Conditions

Temperature: −20° to +70° C (−4° to +158° F)
Humidity: 100% maximum relative humidity

Vibration and Mechanical Shock

All models meet Mil. Std. 202F requirements. Method 201A (Vibration:
10 to 60Hz max., double amplitude 0.06 in, maximum acceleration 10G).
Also meets IEC 947-5-2 requirements: 30G, 11 ms duration, half sine
wave

Certifications

Application Notes

Objects passing inside the specified near limit will produce a false re-
sponse

Indicators

Status LEDs:

Run Mode

Program mode

Green

ON – Power ON, Run mode
Flashing – Output is overloaded

OFF – Program Mode

Red

Flashing – Relative received signal strength

Flashing – Relative received signal strength

Yellow (2)

ON – Output energized (conducting)

ON – Ready for first window limit
Flashing – Ready for second limit
OFF – Not teaching this output

Performance Curves

with Plate Target (Typical)

0

0

200 mm

(8.0 in)

400 mm

(16.0 in)

600 mm

(24.0 in)

800 mm

(32.0 in)

1000 mm

(40.0 in)

50

50

100

100

150

150

200

200

0

2.0 in

2.0 in

4.0 in

4.0 in

6.0 in

6.0 in

8.0 in

8.0 in

DISTANCE

100 x 100 mm

10 x 10 mm

WIDTH

(mm)

Figure 7. 1-Meter Models

0

0

400 mm

(16.0 in)

800 mm

(32.0 in)

1200 mm

(48.0 in)

1600 mm

(64.0 in)

2000 mm

(80.0 in)

100

100

200

200

300

300

400

400

0

4.0 in

4.0 in

8.0 in

8.0 in

12.0 in

12.0 in

16.0 in

16.0 in

100 x 100 mm

DISTANCE

WIDTH

(mm)

Figure 8. 2-Meter Models

U-GAGE® T30 Series with Dual Discrete Outputs

P/N 059200 Rev. E

www.bannerengineering.com - tel: 763-544-3164

5