Features, Power i/o (on/off), Emergency stop – GBC 62fm User Manual

Page 16: Safety shield, 62fm l, Operating instructions, Aminator, I/o (o

Advertising
background image

Operating Instructions

5-4

62FM L

AMINATOR

Emergency stop

button

Control panel

Safety shield

Safety

shield

interlock

latch

Heat rollers

Foot switch

Tension knobs

Roller handle

Tension knob

Idler bar

Feed table

Film shaft

Rewind

Fig. 5-4. 62FM Laminator Identification.

F

EATURES

P

OWER

I/O (O

N

/O

FF

)

Located at the back left of the machine applies
power to the laminator. The control panel display will
illuminate when switch is rotated to the

“l” position.

The off position, marked

“O”, removes power from

the laminator.

E

MERGENCY

S

TOP

Two emergency stop buttons exist on the laminator.
One on each side of the upper cabinet. To engage,
press either push button, roller movement is
stopped. To disengage, turn the push button
clockwise once the emergency condition has been
resolved.

S

AFETY

S

HIELD

Prevents entanglement, entrapment and inadvertent
contact with the heat rollers.

The laminator will

operate in the continuous mode only when
the safety shield is located in the fully locked
position.
The foot switch operates the rollers at 3
fpm (0.9 mpm). The safety shield is removed only
when you load films or clear jams.

To remove the safety shield, unlock the safety shield
interlock latch and lift the safety shield up and away
from the safety shield mounting pins.

This shield must also be used on the rear of the
laminator when the laminator is operated from the
rear.

Advertising