Troubleshooting, 62fm l, Operating instructions – GBC 62fm User Manual

Page 36: Aminator

Advertising
background image

Operating Instructions

7-2

62FM L

AMINATOR

SYMPTOM

POSSIBLE CAUSE

CORRECTIVE ACTION

The control panel display
does not illuminate when
POWER I/O is in the ON,
marked

“I”, position.

Laminator not connected to electrical
supply.

Insert attachment plug into receptacle.

Heat rollers do not turn when
I press the

Run button.

Safety shield is not properly installed.

Remove safety shield and properly
replace it.

Feed table not properly installed

Tilt feed table and properly replace it.

Emergency Stop is engaged

Pull out on the emergency stop push
button.

Heat rollers only turn if I use
the foot switch.

Laminator is in foot switch mode.

Disengage the foot switch mode.

Rear controls do not
operate.

Rear controls are not enabled.

Enable rear controls.

Safety shield is not installed in rear
position.

Install the safety shield.

Laminated items exhibit
curling.

Tension between the top and bottom film
roll is unequal.

Adjust film tension.

Tension on top or bottom roll of film is
too film loose.

Adjust film tension.

Bottom film roll may be improperly
loaded.

Make sure bottom roll of film is around
idler bar and the it is in the normal
operating position.

Adhesive deposited on heat
rollers.

Top and bottom film webs not aligned.

Release heat and pull roller pressure,
align the rolls of film.

Laminate improperly loaded.

Adhesive (matte) side of laminate film
may be against the heat rollers. Unweb
and reload the film properly.

T

ROUBLESHOOTING