background image

© 2002 IBICO

Page 5-4

Patriot 25 E

Operations Manual

5.3 Feed table

To remove

1.

Lift the safety shield to its full upright position.

2.

Slide the feed table interlock latch to the right.

3.

Lift the rear of the table (the rounded side) upwards

and then away from the laminator.

Raise safety

shield

Lift up the table and out

To replace

1.

Set the front of the feed table (the side that is not

rounded) into the table brackets first.

2.

Lower the rear of the feed table onto the table support

bar.

3.

Slide the table interlock latch to the left.

4.

Lower the safety shield to its fully closed position.

5.4 Supply shaft

To remove

1.

Slide the upper shaft to the right from the front operating

position.

2.

While pushing in on the supply shaft to the right, remove

the left side of the shaft from the brake assembly.

3.

Raise the safety shield and remove the table and repeat

the steps above for the lower supply shaft.

To replace

1.

Align the rounded end of the supply shaft into the supply

shaft hole located on the right side of the laminator from
the front operating position.

2.

Push the supply shaft in while aligning the hex end of

the supply shaft with the brake assembly.

5.5 Film alignment

The film supply shafts come with pre alignment holes on
the right side for 9 in. (21 cm), 12 in. (31 cm), 18 in. (46
cm) , 25 in. (64 cm) and 27 in. (69 cm) film widths. Loosen
the locking screw on the right side core adapter and move
the to the corresponding hole to match the width of your
roll of film. Tighten the locking screw in the pre drilled
hole.

Core adapters

Thumb screws

Advertising