Patriot 25E

Page 7-3

Symptom

POWER lamp does

not illuminate when ON/ OFF
isin the ON position.

Heat rollers do not turn.

Laminated items exhibit

wrinkles.

Adhesive deposited on the

heat rollers.

Unsatisfactory adhesion of

laminate.

Possible cause

Laminator not connected to the
electrical supply.

Circuit breaker open.

Safety shield in upright position.

Feed tray interlock pin not in place.

Tension on top or bottom roll of
film is too loose.

Bottom film roll may be improperly
loaded.

Top and bottom film webs not
aligned.

Laminate improperly loaded.

Speed setting too fast for type of
material being laminated.

Insufficient heat.

Laminate improperly loaded.

Heat rollers require cleaning.

Laminated item unsuitable for
adhesion.

Figure 7.3.1 Troubleshooting guide

Corrective action

Insert attachment plug into receptacle.

Reset circuit breaker.

Lower safety shield.

Slide interlock lever all the way into the left side
frame.

Adjust tension per section Film Tension
Adjustmen
t.

Makesure the bottom roll of film is around the
idler bar.

Align film webs per section Film Alignment.

Adhesive (matte) side of laminate film may be
against the heat rollers. Load film per procedure
outlined in section Film Loading and
Threading
.

Lower speed setting by pressing SLOW.

READY must be illuminated.

Adhesive side of film must be facing away from
the heat rollers. Bottom roll of film not threaded
behind the idler bar.

Clean heat rollers per section To Clean The
Rollers
.

Item may be dirty or may have non-porous
surface that is extremely difficult to laminate.