Ab b, Sync hr onization & t imecode – Sound Devices PIX 270i User Manual

Page 50

Advertising
background image

PIX 270i User Guide and Technical Information

v. 2.10

Features and specifications are subject to change. Visit www.sounddevices.com for the latest documentation.

44

Sync

hr

onization & T

imecode

Multiple Cameras with Genlock Input, all Genlocked from a Single PIX

SDI/HDMI

SDI/HDMI

Genlock

A

A

B

B

In this scenario, a PIX 270i is the master sync source for multiple cameras, each with or without their

own PIX acting as a recorder. Because of this locked connection, the cameras can be run indefinitely

and be assured of frame-accurate sync with no possibility of drift.

Set the output of the sync generator to a selected rate and connect the PIX 270i Sync Out (Genlock)

and timecode output to multiple cameras (“mult” the genlock output). This connection uses the PIX

270i as both the video sync source and timecode source. Heads and tails sync for the camera and PIX

files will be perfect.

Camera #1 to PIX #1, Camera #2 to PIX #2, No Genlock

SDI/HDMI

SDI/HDMI

A

A

B

B

In this scenario, each camera is its own master video sync source , but the PIX 270i is the source of

the timecode. The PIX 270i records its files based on the camera’s clock. The heads will match per-

fectly, but the tails may drift depending on the cameras’ clocks.