Se tup menu op tions – Sound Devices PIX 270i User Manual

Page 82

Advertising
background image

PIX 270i User Guide and Technical Information

v. 2.10

Features and specifications are subject to change. Visit www.sounddevices.com for the latest documentation.

76

Se

tup Menu Op

tions

#

Parameter Name

Description

Options

3

Timecode Mode

Sets the running mode for the internal timecode gen-

erator and/or the method which the PIX 270i receives

SMPTE timecode..

• Off
• Freerun
• Freerun Auto Mute
• Record Run
• 24h Run
• 24h Run Auto Mute
• Ext TC (LTC)
• Ext TC (LTC Halt)

» Ext TC (SDI, HDMI)

4

Frame Rate (Audio Only)

The frame rate of timecode stamped to .wav files

(Audio Mode). This setting is ignored in Video Mode.

• 23.976
• 24
• 25

» 29.97
• 29.97 DF
• 30
• 30 DF

5

Drop Frame Enable

Enable or disable drop frame timecode.

» Off
• On

6

Sync Out

Determines whether the signal on the Sync Output

BNC is genlock or wordclock, and determines the

sync reference for that signal. When settings of a

resolution / frame rate are selected, the Sync Out

BNC will supply genlock signal at the specified rate

that reference the internal Ambient® Lockit.

» Off
• 1080p30
• 1080p29.97
• 1080p25
• 1080p24
• 1080p23.976
• 1080i60/PsF30
• 1080i59.94/PsF29.97
• 1080i50/PsF25
• 1080PsF24
• 1080PsF23.976
• 720p60
• 720p59.94 (29.97)
• 720p50
• 720p30
• 720p29.97
• 720p25
• 720p24
• 720p23.976
• 576i50 (PAL)
• 480i59.94 (29.97 NTSC)
• Genlock, Follows Video In
• Wordclock, Follows Video In

7

Auto-Record Hold Off

Sets the duration that a valid timecode sig-

nal has to be recognized by the PIX 270i

before generating a new take when using ex-

ternal timecode to trigger recording (When

[Remote Control - Rec Start/Stop] is set to

Timecode.

» 0 sec
(numeric 0-8)

8

Jam Received TC

Opens a dialog that displays incoming timecode

value in realtime (RxTC), incoming userbits (UB),

transmitting/internal (Ambient® Lockit) timecode value

(GENTC), and transmitting/internal userbits (UB).

• Push Control Knob to jam inter-

nal timecode to incoming (RxTC)

timecode.
• Push MENU to back out.

9

Jam time Of Day

Sets the internal timecode clock to the current time

of day.

10

Set Generator TC

Sets the Ambient® Lockit timecode generator value in

HH:MM:SS.FF format.

» 00:00:00.00
(Timecode value)

Advertising