Powering, Powersafe, Sync hr onization & t imecode – Sound Devices PIX 270i User Manual

Page 52

Advertising
background image

PIX 270i User Guide and Technical Information

v. 2.10

Features and specifications are subject to change. Visit www.sounddevices.com for the latest documentation.

46

Sync

hr

onization & T

imecode

Powering

The PIX 270i features an advanced powering system with 2 redundant DC Inputs (on rear XLR4M

connections) and PowerSafe technology. Two power sources can be attached simultaneously. When

multiple power sources are connected, the PIX 270i will use only one source at a time. The order of

precedence for power sources is:

1. DC Input 1 (Primary power source)
2. DC Input 2 (Secondary power source)
3. PowerSafe circuitry (Shutdown)

By default, the PIX 270i will operate from the Primary power source. When the Primary power

source is removed (or its voltage drops below 9V), the PIX 270i switches to the Secondary power

source without interruption, if available. When operating from the Secondary power source, if the

Primary power source voltage rises above 10.5V, the PIX 270i switches to the Primary power source

without interruption.

PowerSafe

When power is removed or voltage drops below the threshold and no Secondary power source is

available, PowerSafe circuitry will activate. The PIX 270i displays a warning, stop any active record-

ings, finish writing files, and shut the PIX 270i down. The PowerSafe Battery will power the PIX 270i

during this time. This feature ensures that files will be protected even in the event of unexpected

power loss.

Advertising