Remote control, Network, Remote control network – Sound Devices PIX 270i User Manual

Page 85: Se tup menu op tions

Advertising
background image

PIX 270i User Guide and Technical Information

79

Se

tup Menu Op

tions

Remote Control

#

Parameter Name

Description

Options

1

RS-422

Enable or disable RS-422 capability

• On

» Off

2

RS422 Interface Device ID

Set the DeviceID communicated to attached RS422

controllers.

» Sony BVW75
• Sound Devices

3

Rec Start/Stop

Determines what method the PIX 270i uses to auto-

matically start and stop recordings.

» Off
• SDI Flag - RED
• SDI Flag - Panasonic
• SDI Flag - Panasonic (Varicam)
• SDI Flag - Canon
• SDI Flag - Sony
• SDI Flag - Arri
• SDI Flag - PIX
• Timecode

4

GPIO Inputs

Set GPIO inputs (pins 1, 2, and 3 on GPIO connector)

to active high or active low. Active high: Connecting

the pin to +5V will activate the function. Active low:

Connecting the pin to ground will activate the function.

» Active low
• Active high

5

GPIO Outputs

Set GPIO outputs (pins 6, 7, and 8 on GPIO connec-

tor) to active high or active low. Active high: When the

function is true, +5V will appear on the pin. Active low:

When the function is true, the pin will be grounded.

• Active low

» Active high

Network

#

Parameter Name

Description

Options

1

This PIX’s Name

Sets name of PIX 270i. This must be unique within a

network.

» PIX270

2

Grouping

Sub-menu for network grouping settings.

2.1

Network Group

Groups with other PIX 250i, PIX 260i, PIX 270i, and

970 units on the network.

» No Group
• Group 1
• Group 2
• Group 3
• Group 4

2.2

Push Settings to Group

Copies this unit’s settings to all other units in the

group. All grouped settings will be pushed. (

See

“Grouped Settings”, page 47

)

2.3 Synchronize audio channel

settings

3

Dante Redundancy Mode

When On the PIX 270i’s Primary and Secondary

Ethernet ports both transmit Dante Audio over sepa-

rate networks. This provides a fail safe of the Dante

system if one of the networks should fail.

In Dante

Redundancy Mode, two separate networks
must be run and they CANNOT be connect-
ed to one another. Connect any computer
running Dante Controller to the PIX 270i’s
PRI Ethernet network.

» Off
• On

4

Auto IP Settings

When On, the IP settings will automatically be pro-

vided by a DHCP (recommended), or Link-local when

no DHCP is present. When Off the IP Address, Subnet

Mask, and Gateway will have to be entered manually.

• Off

» On

5

IP Address

Displays IP Address, can be edited when Auto IP

Settings is OFF.

Advertising