SPECIFICATIONS

2-2

Manual No. 0-4748

ULTRA-CUT 100

2.06 Specifications & Electrical Requirements

Input Power & Current

208/230V - 460V, 1/3 ph, 50 / 60 Hz

Max OCV (U

0

)

380 vdc

Minimum Output Current

10 Amps

Max Output Current

100 Amps

Output Voltage

60 - 230 vdc

Duty Cycle Rating

100% @ 100A, 180V

Ambient Temperature
for Duty Cycle Rating

104F° (40°C)

Operating range

14°F to 122°F (-10°C to + 50°C)

Power Factor

0.70 @ 100 A DC Output

Cooling

Forced Air (Class F)

Ultra-Cut 100 Specifications & Design Features

Input

Power Input

Current

Suggested Sizes (See Note)

Voltage

Freq.

3-Ph

3-Ph

Fuse (Amps)

Wire (AWG)

(Volts)

(Hz)

(kVA)

(Amps)

3-Ph

3-Ph

208

50/60

23

64

80

#4

1

230

50/60

24

60

80

#4

1

400

50

28

40

50

#6

1

400 (CE)

50

28

40

50

#6

1

460

50/60

26

33

40

#8

1

Ultra-Cut 100 Power Supply

Line Voltages with Suggested Circuit Protection and Wire Sizes

Based on National Electric Code and Canadian Electrical Code

1

Extra Hard Usage Type SO, SOW, SOO, SOOW, ST, STW, STO, STOW, STOO, STOOW

2.07 System Component Layout

Primary power

Work

CNC

Remote

Arc

Starter

Art # A-07328_AB

Torch

Coolant Supply

Coolant Return

Control Cable

Pilot

Return

Coolant Supply

Coolant Return

Plasma Gas

Shield Gas

Work Cable

Fiber
Optic

Cable

Control

Cable

Gas Control

Module

Power
Supply

Torch

Valve

Assembly

Positioning Tube

Plasma Gas

Preflow Gas

Water Shield

Shield

Shield Gas

Negative

Pilot

Return

Control Cable

100’ / 30.5 m Maximum Length

125’ / 38.1 m Maximum Length

175’ / 53.3 m Maximum Length

Shield

I

J

G

K

L

P

O

A,

B,

C,

D,

E

H,

Q,

R,

S,

T