INSTALLATION
3-40
Manual No. 0-4748
ULTRA-CUT 100
7.
Connect the wire lead from the height finder to the ohmic clip if using ohmic torch height
sensing.
Ohmic Clip
Art # A-03393_AB
NOTE
Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically with the
ohmic sensing circuit.