Section 4: operation, 01 introduction, 02 functional overview – Tweco XTTM-301 User Manual

Page 39: 03 getting started

Advertising
background image

Manual 0-4768

4-1

OPERATION

SECTION 4:

OPERATION

4.01 Introduction

This Section provides a description of the XT

TM

-301 Torch

followed by operating procedures.

4.02 Functional Overview

The Torch operates with the Merlin

®

1000 Power Supply

to provide a plasma cutting system which can cut most
metals from gauge thickness up to 1 inch (25.4 mm).

4.03 Getting Started

Follow this procedure at the start of each shift:

WARNING

Disconnect primary power at the source before as-
sembling or disassembling stacked modules, indi-
vidual modules, torch parts, or torch and leads as-
semblies.

A. Torch Parts

Check the torch for proper assembly. Install proper
torch parts for the desired application (refer to Sec-
tion 6.05, Torch Parts Selection).

B. Input Power

1. Check the power source for proper input voltage.

2. Make sure that the Power Supply in the system is

set for the proper voltage (refer to Power Supply
Operating Manual for connections or adjust-
ments).

3. Close main disconnect switch or plug unit in to

supply primary power to the system.

C. Work Cable

Check for a solid work cable connection to the work-
piece.

D. Gas Supplies

Select desired gas supplies. Make sure gas sources
meet requirements (refer to Section 2.03, Specifica-
tions & Design Features). See the Appendix for gas
selection guidance. Check connections and turn gas
supplies on.

E. Purge System

On the Power Supply place the ON/OFF switch to the
ON position. An automatic gas purge (pre-flow) will
remove any condensation that may have accumulated
in the torch and leads while the system was shut
down. The torch cannot be activated during the purge
cycle (pre-flow). After the purge is complete, if the
RUN/SET switch is in SET position, gas will flow. If
the switch is the in RUN position there will be no gas
flow.

F. Current Output Level

Set the desired current output level on the Power Sup-
ply for the desired operation.

NOTE

DO NOT exceed the amperage rating of the Torch
Parts (consumables).

G. Pressure And Flow Settings

Make the pressure and flow settings at the Gas Con-
trol Panel on the Plasma Power Supply.

NOTES

Refer to appropriate Plasma Power Supply Operat-
ing Manual for instructions on setting gas flows.

Refer to Cutting Speed Charts in the Appendix for
recommended gas pressures and flows for the mate-
rial being cut.

H. Ready for Operation

Return the RUN/SET switch to RUN position.

The system is now ready for operation.

NOTE

Refer to Appendix 1 for a detailed block diagram of
the Sequence Of Operation.

Advertising