Stainless steel, 100a, H35 plasma / n2 secondary – Tweco XTTM-301 User Manual
Page 82
APPENDIX
A-8
Manual 0-4768
Stainless Steel
100A
H35 Plasma / N2 Secondary
Art # A-06746
Tip
35-1272
Electrode
Shield Cap
35-1034
35-1062
35-1080
35-1041
Cartridge
Shield Cup
35-1016
Plasma Gas Distributor
Shield Gas Distributor
35-1020
Shield
(N2)
(ga)
(in)
(in)
Ball
psi
psi
(volts)
(in)
±0.005
(ipm)
(in)
(sec)
3/8
0.375
45
90
35
142
0.130
50
0.250
0.5
1/2
0.500
45
90
35
145
0.130
37
0.250
0.5
5/8
0.625
45
90
35
153
0.140
26
0.250
0.6
3/4
0.75
45
90
35
155
0.160
20
1
1.00
45
90
35
165
0.160
10
Shield
(N2)
Ball
bar
bar
(volts)
(mm)
±0.125
(mm/min)
(mm)
(sec)
45
6.2
2.4
143
4.1
1000
6.4
0.5
45
6.2
2.4
151
4.1
740
6.4
0.6
45
6.2
2.4
156
4.1
460
45
6.2
2.4
164
4.1
270
Edge Start
100A SS (H35/N2)
Edge Start
Edge Start
Edge Start
Torch
Working
Height
Travel
Speed
Initial
Piercing
Height
Material
Thickness
Pierce
Delay
Material
Thickness
** Arc
Voltage
Cut Flow Rates / Pressures
Plasma (H35)
Bold Italic type indicates edge starts only.
(mm)
25
20
15
12
** Arc
Voltage
Cut Flow Rates / Pressures
Plasma (H35)
Torch
Working
Height
Travel
Speed
Initial
Piercing
Height
Pierce
Delay