Aluminum, 100a, N2 plasma / h2o secondary – Tweco XTTM-301 User Manual

Page 86

Advertising
background image

APPENDIX

A-12

Manual 0-4768

Aluminum

100A

N2 Plasma / H2O Secondary

NOTE

Ohmic sensing is not recommended with water shield. Water on the
plate interferes electrically with the ohmic sensing system.

Art # A-06747

Shield Cap

35-1053

35-1089

35-1041

Cartridge

Shield Cup

35-1016

Plasma Gas Distributor

Shield Gas Distributor

35-1020

35-1034

35-1272

Tip

Electrode

Shield (H2O)

(ga)

(in)

(in)

Ball

psi

Ball*

(volts)

(in)±0.005

(ipm)

(in)

(sec)

10

0.135

45

90

5

158

0.188

170

0.300

0.0

3/16

0.188

45

90

5

165

0.188

80

0.300

0.3

1/4

0.250

45

90

5

167

0.188

60

0.300

0.3

3/8

0.375

45

90

5

172

0.188

50

0.300

0.3

1/2

0.500

45

90

5

168

0.188

35

0.300

0.4

5/8

0.625

45

90

5

179

0.188

20

0.350

0.5

Shield (H2O)

Ball

bar

Ball*

(volts)

(mm)

±0.125

(mm/min)

(mm)

(sec)

45

6.2

5

161

4.8

3350

7.6

0.3

45

6.2

5

165

4.8

1960

7.6

0.3

45

6.2

5

167

4.8

1640

7.6

0.3

45

6.2

5

170

4.8

1390

7.6

0.3

45

6.2

5

171

4.8

1210

7.6

0.4

45

6.2

5

169

4.8

970

7.6

0.4

45

6.2

5

176

4.8

610

8.9

0.6

Bold type indicates maximum piercing parameters.

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

100A Al (N2/H2O)

Initial

Piercing

Height

Pierce

Delay

Material

Thickness

** Arc

Voltage

Cut Flow Rates / Pressures

Plasma (N2)

** Arc

Voltage

Torch

Working

Height

15

* Ball setting for shield water is set using a line pressure of 55 PSI / 3.8 bar

12

10

8

6

5

4

Travel

Speed

Material

Thickness

(mm)

Cut Flow Rates / Pressures

Plasma (N2)

Advertising