AUTO-CUT 200 XT

A-2

APPENDIX

Manual 0-5286

CNC FUNCTIONS.

CNC I/O circuits provide at least 1000V galvanic isolation from the plasma power supply.

While the CNC circuits are isolated from the power supply, many of the signal returns on J15 and TB1 & 2 are com-

mon to each other. J15 pins 1, 4, 5 & 10 and TB1-1, 5, 7, 9, and TB2-1 & 3 are all common. J15 pin 12 and TB2-10 are

also connected to the others when SW6 (OK to Move select) is set for voltage.

Rear Panel CNC Connector J15:
14 Circuit (Amp CPC) Remote Standard:
Chassis gnd (for SC-11 cable shield)

1

1

Start/Stop

3 (+); 4 (-)

1

Ok to Move (contacts or voltage

2

)

12(-); 14 (+)

1

Divided Arc volts (selectable

ratio 50:1; 40:1; 30:1; 16.6:1, 25:1)

5 (-); 6 (+)

PreFlow ON

7 (+); 9 (-)

Corner Current Reduction

10 (+); 11 (-)

Isolated Circuit Comm (for SC-11)

8

Chassis Gnd

13

1

These are also duplicated on TB1, TB2 & TB3 use one or the other not both. Additional functions are only available

on TB1, TB2 & TB3.

2

SW6 on CCM I/O PCB selects OK to Move for isolated contact closure or DC Volts (15-18V) at <100ma. When

set for contacts, OK to Move circuit is rated for 120 VAC / 28 VDC @ 1A.

Internal CNC connections. TB1, TB2 & TB3 on CCM module.

Connections are provided on the CCM module TB1, TB2 & TB3 terminal blocks including most of the rear panel

functions plus some additional features. All these signals are isolated from the plasma power supply but signals

marked (comm.) and (-) are common to each other.

Users are expected to install their own CNC cable to these connections. Knockout hole is provided in rear panel of

CCM module. User shall provide strain relief / cord grip for user installed cable.

TB1

Function

Connection

CNC Enable/Disable

TB1-2 (+), TB1-1(-)(comm.)

OK to Move 2

TB1-3 &TB1-12 Contacts only, rated 1A @ 28 VAC/DC

Stop Latched (NC)

TB1-4 (+) & TB1-5 (-) (comm.) used with Start Latched

Start/Stop Ret

TB1-6 (+), TB1-5 (-) (comm.)

or Start Latched (NO)

TB1-6 (+), TB1-5 (-) (comm.) used with Stop Latched

Divided Arc Voltage

TB1-8 (+), TB1-7 (-) comm.

Remote Analog Current Control

TB1-9 Analog Comm. (-) or 10K CC Pot low

TB1-10 Analog in (+) or CC Pot Wiper

TB1-11 10K CC Pot Hi (+10V @ 1 ma. Supply)