Section 3: installation, 01 installation requirements, Section 3: installation -1 – Tweco 300 XT Auto-Cut 380V User Manual

Page 25: Installation requirements -1, Auto-cut 300 xt

Advertising
background image

AUTO-CUT 300 XT

Manual 0-5261

INSTALLATION

3-1

SECTION 3: INSTALLATION

3.01 Installation Requirements

Electric Supply

The electrical supply network, the gas and water supply system must meet local safety standards. This

conformity must be checked by qualified personnel.

Auto-Cut 300 XT™ Power Supply

Input

Power Input

Current

Suggested Sizes (See Note)

Voltage

Freq.

3-Ph

3-Ph

Fuse (Amps) Wire (AWG) Wire (mm

2

)

(Volts)

(Hz)

(kVA)

(Amps)

3-Ph

3-Ph

3-Ph

380

50/60

63

97

150

#4

25

IEC

380

50/60

71

110

150

#4

25

NOTE

* Suggested wire size based on United States NFPA 70 National Electrical Code 2011 edition published by the
National Fire Prevention Association. Listings are from table 400.5(A)(2) for flexible cord of certain types rated
for 75 deg C in ambient temperatures up to 30 deg C. Using wires of lower temperature rating or different insu-
lation type may require larger wire size. Derate for higher ambient.
These are suggestions only. Always refer to your local and national codes that apply to your region for final
determination of correct wire type and size.

CAUTION

Fuse and wire sizes are for reference only. The installation must conform to national and local codes for the type
and method of wire being used.

Gas Supply

The customer must supply all gas and pressure regulators. Gases must be of high quality. Pressure regula-

tors must be double-stage and installed as close as possible to the gas console. Contaminated gas can cause

one or more of the following problems:

• Reduced cutting speed
• Poor cut quality
• Poor cutting precision
• Reduced consumables life.
• Oil or grease contamination from compressed or bottled air can cause fires in conjunction with oxygen.

Cooling System Requirements

Coolant must be added to the system on installation. The amount required varies with torch leads length.

Victor Thermal Dynamics recommends the use of its coolants 7-3580 and 7-3581 (for low temperatures).

Coolant Capabilities

Cat. Number and Mixture

Mixture

Protects To

7-3580 ‘Extra-Cool

TM

25 / 75

10° F / -12° C

7-3581 ‘Ultra-Cool

TM

50 / 50

27° F / -33° C

7-3582 ‘Extreme Cool

TM

Concentrate*

-65° F / -51° C

* For mixing with D-I Cool

TM

7-3583

Advertising