Auto-cut 300 xt – Tweco 300 XT Auto-Cut 380V User Manual
Page 56
AUTO-CUT 300 XT
�-�
OPERATION
Manual 0-5261
Code
Message
Remedy / Comments
225
Inverter 1A Incom-
patible Revision
Unsupported Inverter Revision; Ribbon cable CCM J31 to Inverter Module 1 Section A dam-
aged; CCM code version incompatible with Inverter revision or model
226
Inverter 1B Incom-
patible Revision
Unsupported Inverter Revision; Ribbon cable CCM J32 to Inverter Module 1 Section B dam-
aged ; CCM code version incompatible with Inverter revision or model
227
Inverter 2A Incom-
patible Revision
Unsupported Inverter Revision; Ribbon cable CCM J33 to Inverter Module 2 Section A dam-
aged; CCM code version incompatible with Inverter revision or model
228
Not used
Reserved for other model with another inverter section
229
Inverter 3A Incom-
patible Revision
Unsupported Inverter Revision; Ribbon cable CCM J35 to Inverter Module 3 Section A dam-
aged ; CCM code version incompatible with Inverter revision or model
230
Inverter 3B Incom-
patible Revision
Unsupported Inverter Revision; Ribbon cable CCM J36 to Inverter Module 3 Section B dam-
aged ; CCM code version incompatible with Inverter revision or model
231
Inverter 1A VAC
Mismatch
Inverter AC Voltage rating incompatible with Power Supply voltage rating; Ribbon cable
CCM J31 to Inverter Module 1 Section B damaged or loose; Wrong voltage Inverter Module 1
installed; Defective Inverter module
232
Inverter 1B VAC
Mismatch
Inverter AC Voltage rating incompatible with Power Supply voltage rating; Ribbon cable
CCM J32 to Inverter Module 1 Section B damaged or loose; Wrong voltage Inverter Module 1
installed; Defective Inverter module
233
Inverter 2A VAC
Mismatch
Inverter AC Voltage rating incompatible with Power Supply voltage rating; Ribbon cable
CCM J33 to Inverter Module 2 Section A damaged or loose; Wrong voltage Inverter Module 2
installed; Defective Inverter module
234
Not used
Reserved for other model with another inverter section
235
Inverter 3A VAC
Mismatch
Inverter AC Voltage rating incompatible with Power Supply voltage rating; Ribbon cable
CCM J35 to Inverter Module 3 Section A damaged or loose; Wrong voltage Inverter Module 2
installed; Defective Inverter module
236
Inverter 3B VAC
Mismatch
Inverter AC Voltage rating incompatible with Power Supply voltage rating; Ribbon cable
CCM J36 to Inverter Module 3 Section B damaged or loose; Wrong voltage Inverter Module 3
installed; Defective Inverter module
237
Too Few Inverters
Found
Two or more Inverter Sections required to operate; Ribbon cable from CCM to Inverter Section
damaged or disconnected;
238
BIAS VAC Invalid
Invalid AC Voltage Selection; Damaged or loose connection at J61 of System Bias Supply
239
AC Voltage High
System Bias PCB detected AC Voltage is higher than Power Supply rated Voltage; System
Bias Supply J61 Voltage Selection connection damaged or disconnected; Defective System
Bias PCB; Defective CCM
240
AC Voltage Low
System Bias PCB detected AC Voltage is lower than Power Supply rated Voltage; System
Bias Supply J61 Voltage Selection connection damaged or disconnected; Defective System
Bias PCB; Defective CCM
241
Inverter 1A Input
Voltage Error
Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of Inverter
Module 1 Section A; Poor AC Power Quality; Defective W1 contactor; Loose or open connec-
tion between input terminals and W1 contactor or contactor and input of Inverter Section;
Defective Inverter module
242
Inverter 1B Input
Voltage Error
Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of Inverter
Module 1 Section B; Poor AC Power Quality; Defective W1 contactor; Loose or open connec-
tion between input terminals and W1 contactor or contactor and input of Inverter Section;
Defective Inverter module
243
Inverter 2A Input
Voltage Error
Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of Inverter
Module 2 Section A; Poor AC Power Quality; Defective W1 contactor; Loose or open connec-
tion between input terminals and W1 contactor or contactor and input of Inverter Section;
Defective Inverter module