05 connect input power and ground cables, Connect input power and ground cables -5, Auto-cut 300 xt – Tweco 300 XT Auto-Cut 380V User Manual

Page 29

Advertising
background image

AUTO-CUT 300 XT

Manual 0-5261

INSTALLATION

3-5

3.05 Connect Input Power and Ground Cables

Connect Input Power and System Ground Cables

1. Remove the input power cover to the right of the coolant filter at the rear of the power supply. To do this

remove the two screws then lift up and pull away.

2. Carefully cut back the outer sheath on the primary input power cable to expose the individual wires. Cut

back the insulation on the individual wires. Route the cable upward through Input Power Port at the bottom

of the panel. There are 2 extra plates included at the cable entrance. Discarding one or both allows changing

the opening size for larger cable/strain relief.

3. Install stripped end of 3 phase wires into the terminal block L1, L2 and L3 and connect the individual cables

as shown.

4. Connect the power cable ground wire to the ground terminal block.

5. Route a system ground cable (F1) to the stud on the rear of the gas control/arc starter Refer to the Ground

Connections Section for full details and procedures on proper system grounding.

Ground Terminals

Art # A-11916

Factory installed

Ground (F)

COOLANT

RETURN SUPPLY

Input Power

and Ground

1/0 Ground (F1)

to ‘Star’ Ground

Stud

Advertising