Auto-cut 300 xt – Tweco 300 XT Auto-Cut 380V User Manual

Page 38

Advertising
background image

AUTO-CUT 300 XT

3-1�

INSTALLATION

Manual 0-5261

3.13 Connect Torch Leads to the Gas Control Module / Arc Starter

1. Remove the top cover from the Gas Control Module / Arc Starter.

2. Pass the torch leads and coolant leads through the torch leads port on the back of the module. Ensure that the

leads outer jacket slides into the port.

CAUTION

Use protective gloves when handling the leads. Do not kink or bend the leads.

3. Inside the module, slide the leads clamp over the leads.

4. Connect the leads to the module in the sequence shown. Coolant leads and connectors are color-tagged; red

for coolant return, green for coolant supply. Shield gas and plasma gas connections are left- and right- hand

threaded and will not interchange.

Clamp * (Clamp type may vary)

Art # A-11929

2

Torch Leads: Coolant Supply & Return
Plasma Gas
Shield Gas

1

3

Advertising