Appendix 8: serial communications, A8.01 cables and switch settings for 2 and 4 wire, Ultra-cut 100 – Tweco 100 Ultra-Cut(March 2013) User Manual

Page 144: Rs 485 wiring (2 wire, half duplex)

Advertising
background image

APPENDIX

A-12

Manual 0-5132

ULTRA-CUT 100

APPENDIX 8: SERIAL COMMUNICATIONS

A8.01

Cables and Switch Settings for 2 and 4 Wire

The CCM communicates with the TSC 3000 (touch screen HMI panel) using RS 485 (2 wire, half duplex). When a CNC
controller is used in place of the TSC the CCM can be reconfigured for RS 422 (4 wire, half duplex) if supported by the
CNC. RS 422 is normally full duplex but the CCM only supports half duplex. RS 232 is not directly supported.
Converters are available from various sources to convert RS 232 to RS 485/422. When possible, the 4 wire configurationisIt
is recommended to use the 4 wire configuration when possible for easier troubleshooting. The serial communication
port of the CCM is provided with 3KV isolation from the rest of the plasma supply circuitry.

RS 485 wiring (2 wire, half duplex)

Art # A-09481

CCM Module

JUMPER
for 2 WIRE
(RS485 only)
use Data +,
Data -, Gnd.

2W

4W

J14

SW14

SW14 - LINE
TERMINATION
norm ally on
(refer to m anual)

KEY PLUG

PLASMA ENABLE

TSC 3000

J54

1
2
3
4
5
6
7
8
9

10
11
12
13
14

REMOTE TSC to CCM CABLE (V):

(OR / W)

(W / BL)

J61

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

(BK)

(R)

(W)

(GN)

(OR)

Data-

Data+

The multicolor wires are twisted pairs.

CCM to TSC 3000 is RS 485 - 2 wire.

OR / W = Orange wire with White stripe

(W / OR)

(W / GN)

(GN / W)

(BL / W)

RS 422 wiring (4 wire, half duplex) (also called RS 485 4 wire)

Ar

t # A-09482_AB

4W

JUMPER for 4 WIRE
use TX+, TX-,
RX+, RX-

2W

(W / GN)

#14

Norm ally open (NO) PLASMA ENABLE (close to enable)
jum per #1 to #3, connect SW to #5 & #6.
Norm ally closed (NC) PLASMA ENABLE (open to enable)
connect SW to #1 & #3 in place of the jumper.
No jum per required.

(W / OR)

#12

SHIELD 1

#1

SHIELD 2

SW14

SW14 - LINE
TERMINATION
norm ally on
(refer to m anual)

CCM Module

J54

1
2
3
4
5
6
7
8
9

10
11
12
13
14

COMMUNICATIONS &
CONTROL CABLE (W)
CNC to CCM

Rx+

Rx-

(W / BL)

#9

(OR / W)

#8

Tx-

Tx+

PLASMA ENABLE NC
(open SW to enable)

#3

J14

Connect both shields to earth ground
at the CNC end of cable.

OR / W = Orange wire
with White stripe.

PLASMA ENABLE NO
(used with jumper)

to CNC Rx+

(OR)

#5

to CNC Rx-

(BL / W)

#10

to CNC Tx-

#6

(GN)

to CNC Tx+

GN / W)

#13

The multicolor wires are twisted pairs.

Signal Gnd

KEY PLUG

(W)

#1

(R)

#2

(BK)

#3

Advertising