06 specifications & electrical requirements, 07 system component layout, Ultra-cut 100 – Tweco 100 Ultra-Cut(March 2013) User Manual

Page 18

Advertising
background image

SPECIFICATIONS

2-2

Manual No. 0-5132

ULTRA-CUT 100

2.06 Specifications & Electrical Requirements

Input Power & Current

208/230V - 460V, 1/3 ph, 50 / 60 Hz

Max OCV (U

0

)

380 vdc

Minimum Output Current

10 Amps

Max Output Current

100 Amps

Output Voltage

60 - 230 vdc

Duty Cycle Rating

100% @ 100A, 180V

Ambient Temperature
for Duty Cycle Rating

104F° (40°C)

Operating range

14°F to 122°F (-10°C to + 50°C)

Power Factor

0.70 @ 100 A DC Output

Cooling

Forced Air (Class F)

Ultra-Cut 100 Specifications & Design Features

Input

Power Input

Current

Suggested Sizes (See Note)

Voltage

Freq.

3-Ph

3-Ph

Fuse (Amps)

Wire (AWG)

(Volts)

(Hz)

(kVA)

(Amps)

3-Ph

3-Ph

208

50/60

23

64

80

#4

1

230

50/60

24

60

75

#4

1

400

50

28

40

50

#6

1

400 (CE)

50

28

40

50

#6

1

460

50/60

26

33

40

#8

1

600

50/60

25

24

30

#8

Ultra-Cut 100 Power Supply

Line Voltages with Suggested Circuit Protection and Wire Sizes

Based on National Electric Code and Canadian Electrical Code

1

Extra Hard Usage Type SO, SOW, SOO, SOOW, ST, STW, STO, STOW, STOO, STOOW

2.07 System Component Layout

Primary power

Work

CNC

Remote

Arc

Starter

Art # A-09124

Torch

Coolant Supply

Coolant Return

Control Cable

Pilot

Return

Coolant Supply

Coolant Return

Plasma Gas

Secondary

Work Cable

DMC-3000

Gas

Console

Ultra-Cut

Power
Supply

DPC-3000

Gas

Control

Positioning Tube

Plasma Gas

Marking

Shield

Shield Gas

Negative

Pilot

Return

Control Cable

100’ / 30.5 m Maximum Length

Shield

H

Q

R

U

S

A

B

C

D

E

P

K

L

O

I

J

G

175’ / 53.3 m Maximum Length

Preflow

Fiber Optic

L

Water Shield

T

F

125’ / 38.1 m Maximum Length

175’ / 53.3 m Maximum Length

Fiber Optic

Control Cable

F

Ground Cable

Only When
DMC Mounted
On Top Of PS

Touch

Screen

Controller

V

W

Advertising