Ultra-cut 100 – Tweco 100 Ultra-Cut(March 2013) User Manual

Page 88

Advertising
background image

OPERATION

4-18

Manual No. 0-5132

ULTRA-CUT 100

Code

Message

Remedy / Comments

4-1

Coolant Level low

Check coolant level, add as needed.

4-2

Low coolant flow

Fault response time: Process Never started since last
power cyle: Below 0.7 GPH for 15 Seconds. Else below 0.5
GPH no delay or after 3 seconds if below 0.7 GPH
Possible cause: Suction leak introducing air into coolant,
suspect rear panel filter seal; clogged filter; defective
pump.

4-3

Coolant overheated

Coolant return temperature exceeded 70 degrees Celcius
(158F). Coolant fan failed; radiator fins clogged with
dirt; operating with side panel loose or removed. Ambient
temperature > 40 deg C.

4-4

Coolant System not ready.

Proper coolant flow of 0.7 GPH was not obtained during
up to 4 minutes of Priming. New installation can require
additional Priming cycle(s) to fill hoses with coolant; cylce
power to restart Priming; Suction leak introducing air into
coolant; suspect rear panel filter seal; Clogged coolant
filter; Damaged torch coolant tube; Defective pump
assembly.

4-5

Low Coolant Level Warning

Low coolant level during cut, does not stop cut.
Add coolant as required.

5-1

CANBUS Acknowledge fault.

Message sent over CANBUS (Fiber-optic) was not
acknowledged as received by DMC. CCM to DMC Fiber-
optic cable not properly connected, dirty or defective;
DMC power supply or Control PCB defective; CCM
defective.

5-2

CANBUS Off

Excessive communication errors resulted in
communication with DMC to turn off. Dirt on fiber ends
or in connectors, blow out with clean dry air; fiber not
locked into connector; sharp bends in fiber; fiber
defective;

5-3

CANBUS Errors Warning.

Communication with DMC has required a signifcant
number of message retries due to communication errors.
Dirt on fiber ends or in connectors, blow out with clean
dry air; fiber not locked into connector; sharp bends in
fiber; fiber defective;

5-4

Reserved

No information available; Contact customer service

6-1

CCM Analog Voltage Error

Replace CCM

6-2

CCM ADC or DAC error

Replace CCM

6-3

Coolant Flow too High

Flow greater than 2.7 gal/min Torch coolant tube
broken or missing; CCM fault, replace CCM

6-4

CCM Data Memory error

Replace CCM

6-5

CCM Program memory fault

Replace CCM

6-6

+5V Logic supply low

Replace CCM

6-7

CCM processor over temp

Reduce ambient tempurature; Defective CCM; replace

6-8

5V supply for RS 485/422
communication low.

Replace CCM

CCM Status Code

Group 4 -- Torch Coolant System

Group 5 -- Gas Control Communications Port

Group 6 -- CCM

Advertising