3.14 DPC-3000 Gas Pressure Control Installation

The DPC-3000 Gas Control must be installed in a suitable location close to the Torch such as the gantry. The unit
must be mounted to a flat horizontal surface. If the Module is mounted to any support subject to vibration or
motion, the installer must fasten the module to the support securely.

The Module should be located as far away as possible from the Arc Starter due to electromagnetic interference. It
is acceptable to locate the control cable in the same track as the cables from the Arc Starter.

The Module includes feet which lift the bottom panel off the mounting surface. There are ventilation holes on the
bottom panel; the space between the bottom panel and the mounting surface must remain open for ventilating air
to enter the module. Louvers on the back panel of the module must also remain unblocked, for the free passage
of ventilating air.

The Module also comes with non metalic isolation grommets for mounting. These must be used in all four
mounting slots to raise the Module so there is nometal to metal contact between the Module and the mounting
surface.

Mounting Dimensions

10.90 in

[276.86 mm]

DPC-3000 Profile

4.00 in

[101.6 mm]

6.64in

[168.7mm]

11.00 in

[279.4 mm]

10.45 in

[265.4 mm]

.30 in
[7.62mm]

DPC-3000 Top

Art # A-09143