Ultra-cut 100 xt – Tweco 100 XT Ultra-Cut Plasma Cutting System User Manual

Page 36

Advertising
background image

ULTRA-CUT 100 XT

3�14

INSTALLATION

Manual 0-5272

Art # A-09677_AB

Hose not secured in

the Strain Relief

Correct installation:

Correct way to pull the cable is to use a snake or a wire or another cable and attach it securely to the hose behind the

strain relief. Then secure the fiber connector to the pulling device leaving some slack in the fiber. Keep the protective

end covers on the fiber until you are ready to connect it to the PCB in the CCM or gas control.

Art # A-09420

Correct installation in CCM or Gas Control leaves a loop of fiber so there is no stress on the fiber where it exits the

connector or the hose.

Art # A-12014

No

sharp

bends

CCM

No

Sharp

Bends

Advertising