ULTRA-CUT 100 XT

Manual 0-5272

INSTALLATION

3-23

3.17 Optional HE400 COOLER

Used in series with the existing cooling system of the Ultra�Cut XT™ series power supplies, the optional HE400

Cooler provides additional cooling when ambient temperatures exceed the units rated temperature.. The HE400

fan is thermally controlled to operate whenever the Ultra-Cut fan and pump is on and the coolant temperature is

above a predetermined level. It may come on anytime while the main pump is operating.

!

WARNING

Do not disassemble the Cooler with the power applied or the coolant flowing. Dangerous 220 AC voltages and high

pressure liquid are present.

Locate the Cooler so that there is adequate ventilation in front of and behind the unit and do not place or stack

anything on top of the unit.

2’ (0.6 m)

2’ (0.6 m)

3”

76 mm

3”

76 mm

Art # A-09623