Install the V-D Board.
1. Locate the V-D Board which should be with the iCNC.
2. Inside the Power Supply, locate and remove the mounting panel’s 2 screws and panel.
3. Install the V�D board standoffs and the V�D Board from the XT iCNC then reattach the panel with the 2 screws,
securing the V-D board in place. If using another V-D Board, follow the instructions provided mounting it
in this same location.
Space for V-D Board
Ohmic clip cable port
V-D Board connection
V-D Board installed
Art # A-12079
V�D Board shown with optional wire harness for iHC controller
Control Cable.
The iHC board can be supplied with a wire harness and connector (shown in previous image), to be installed in
the rear panel hole labeled “Height Control” . The connector mates with a cable from the iHC. For other height
control V�D boards a strain relief can be installed in this hole for those cables. Refer to Appendix for wiring diagram.