ULTRA-CUT 100 XT

3-30

INSTALLATION

Manual 0-5272

2. Reinstall the Arc Starter Cover. Ensure that the ground wire is not crimped between the cover and the base.

Art # A-12059

Lower screws

(2 per side)

Upper screws (2 per side)

Cover

Ground Wire

3. The Arc Starter must be grounded; the grounding terminal is marked . Refer to the previous section for

grounding details.

Ground Cable

Art # A-04758

1 Nut and 1 Washer
Remain in Place

Torch Leads