Ultra-Cut 300 XT™ Power Supply: Gas Pressures, Flows, and Quality Requirements

Gas

Quality

Minimum Pressure

Flow

O

2

(Oxygen)

99.5% Purity

(Liquid recommended)

120 psi

8.3 bar / 827 kPa

200 scfh (5700 l/h)

N

2

(Nitrogen)

99.5% Purity

(Liquid recommended)

<1000 ppm O

2

, <32 ppm

H

2

O)

120 psi

8.3 bar / 827 kPa

300 scfh (8496 l/h)

Compressed

or Bottled Air

Clean, Dry,

Free of Oil (see Note 1)

120 psi

8.3 bar / 827 kPa

450 scfh (12743 l/h)

H35 (Argon-Hydrogen)

H35 = 35% Hydrogen,

65% Argon

99.995% Purity

(gas

recommended)

120 psi

8.3 bar / 827 kPa

200 scfh (5664 l/h)

H

2

O (Water)

See Note 2

50 psi (3.5 bar)

10 gph (38 lph)

Note 1: The air source must be adequately filtered to remove all oil or grease. Oil or grease

contamination from compressed or bottled air can cause fires in conjunction with oxygen.

For filtering, a coalescing filter able to filter to 0.01 microns should be placed as close as

possible to the gas inlets on the Gas Control Module.

Note 2: The tap water source does not need to be deionized, but in water systems with extremely high mineral content

a water softener is recommended. Tap water with high levels of particulate matter must be filtered.

Note 3: Water Pressure Regulator No. 8-6118 is recommended to ensure proper water pressure.

Ultra-Cut 400 XT™ Power Supply: Gas Pressures, Flows, and Quality Requirements

Gas

Quality

Minimum Pressure

Flow

O2 (Oxygen)

99.5% Purity

(Liquid recommended)

120 psi

8.3 bar / 827 kPa

200 scfh (5700 l/h)

N2 (Nitrogen)

99.5% Purity

(Liquid recommended)

<1000 ppm O2, <32 ppm

H2O)

120 psi

8.3 bar / 827 kPa

300 scfh (8496 l/h)

Compressed

or Bottled Air

Clean, Dry,

Free of Oil (see Note 1)

120 psi

8.3 bar / 827 kPa

500 scfh (14158 l/h)

H35 (Argon-Hydrogen)

H35 = 35% Hydrogen,

65% Argon

99.995% Purity

(gas recommended)

120 psi

8.3 bar / 827 kPa

200 scfh (5700 l/h)

H17 17.5% Hydrogen

32.5% Argon

50% Nitrogen

99.995% Purity

(gas recommended)

120 psi

8.3 bar / 827 kPa

200 scfh (5700 l/h)

Ar (Argon)

99.995% Purity

(gas recommended)

120 psi

8.3 bar / 827 kPa

150 scfh (4200 l/h)

H2O (Water)

See Note 2

50 psi (3.5 bar)

10 gph (38 lph)

Note 1: The air source must be adequately filtered to remove all oil or grease. Oil or grease

contamination from compressed or bottled air can cause fires in conjunction with oxygen.
For filtering, a coalescing filter able to filter to 0.01 microns should be placed as close as

possible to the gas inlets on the Gas Control Module.
Note 2: The tap water source does not need to be deionized, but in water systems with extremely high mineral con-

tent a water softener is recommended. Tap water with high levels of particulate matter must be filtered.
Note 3: Water Pressure Regulator No. 8-6118 is recommended to ensure proper water pressure.