22 connecting torch, Connecting torch -31 – Tweco 400 Ultra-Cut(October 2014) User Manual

Page 57

Advertising
background image

ULTRA-CUT 100 XT/200 XT/300 XT/400 XT

Manual 0-5264

INSTALLATION

3-31

3. Connect the gas supply lines and the control cable connector from the Gas Control Module to the Valve Kit as

shown. Hold the check valves stationary while attaching the gas lines. (XTL shown)

Control Cable

Plasma Gas Inlet

Shield Gas Inlet

Preflow Gas Inlet

WMS™ Inlet

Art # A-07646

Exhaust Muffler

CAUTION

Hold all fittings stationary while attaching hoses or leaks can be created. Side pressure can break the

check valves or weaken their connection to the torch valve assembly. All fittings must be checked for

leaks after assembly.

3.22 Connecting Torch

Connect the Torch as follows:

Art # A-09198

Pilot Lead Connector

Torch Head Assembly

Mounting Tube

O-Ring

Torch Leads End Cap

Plasma Gas

(Left Hand Thread)

Shield Gas

(Right Hand Thread)

Coolant Supply

&

Power Lead (-)

Pilot Lead

Coolant Supply,

Coolant Return,

and Pilot Leads

Leads Cover

Groove for O-Ring

To Torch Valve